52 research outputs found

    The FREEDOM Study: does the Saga Continue for Diabetic Patients?

    Get PDF

    Vascular response after implantation of biolimus A9-eluting stent with bioabsorbable polymer and everolimus-eluting stents with durable polymer. Results of the optical coherence tomography analysis of the BIOACTIVE randomized trial

    Get PDF
    AbstractBackgroundIn BIOACTIVE study, we evaluated vascular responses after the implant of biolimus A9-eluting stent (BES; BioMatrixTM) and the everolimus-eluting stent (EES; XIENCE VTM). In this study, we present the optical coherence tomography analysis (OCT) 6 months post-intervention.MethodsPatients were randomized to treatment with BES (n = 22) or EES (n = 18). The primary outcome was the frequency of non-covered, poorly positioned struts by OCT.ResultsOCT was performed in 26 patients (BES: n = 15; EES: n = 11) and 749 tomographic images and 7,725 stent struts were analyzed. BES and EES showed similar luminal and stent areas. Neointimal hyperplasia area, neointimal thickness and the percentage of in-stent obstruction (8.44 ± 5.10% vs. 9.21 ± 6.36%; p = 0.74) were similar. The rates of not covered struts (BES: 2.10 ± 3.60% vs. ESS: 2.46 ± 2.15%, p = 0.77) and poorly positioned struts (BES: 0.48 ± 1.48% vs. EES 0.44 ± 1.05%, p = 0.94) were similarly low. The frequency of frames with signs consistent with peri-strut inflammatory infiltrate was low and similar between BES (15.53 ± 20.77%) and EES (11.70 ± 27.51%; p = 0.68).ConclusionsThe second-generation drug-eluting stents BES and EES were equally effective at suppressing the neointimal formation after 6 months, with favorable vascular responses. The frequency of frames with peri-strut infiltrate signals per patient was low, and lower than that observed historically with first-generation drug-eluting stents

    Arteriografia coronária com cateter de muito baixo perfil. Eficácia e segurança do procedimento e da alta hospitalar aos 60 minutos

    No full text
    OBJETIVO: Avaliar a eficiência, a segurança e a praticidade da angiografia coronária com cateteres 4 French (F), pela técnica de Judkins. MÉTODOS: De agosto/95 a janeiro/96, 70 pacientes com suspeita de insuficiência coronária submeteram-se à cinecoronariografia , utilizando introdutores e cateteres 4F. Após o exame, realizava-se compressão local por 15min e, 60min após, os pacientes eram orientados a caminhar, sob vigilância , sendo dada a alta hospitalar após 4h, . RESULTADOS: A idade variou de 31 a 83 (m = 57) anos, sendo 39 (56%) homens, com peso entre 43 a 101 (m = 69) kg. Obteve-se ótima qualidade de imagem em 62 casos (88%), havendo a necessidade de substituição por cateteres de maior calibre (6 a 8F) em 8 (12%) pacientes. Não ocorreram complicações vasculares ou sangramentos maiores. Em apenas 2 (3%) casos, houve discreto sangramento, resolvido com nova compressão local. Sessenta pacientes (85%) deambularam aos 60±5min e tiveram alta hospitalar com 4h, em média. CONCLUSÃO: A utilização de cateteres 4F por via femoral, para realização de cinecoronariografia permite a deambulação muito precoce (média = 60±5min) e sem complicações hemorrágicas. Verificaram-se pequena utilização de contraste (média = 60ml) e redução da permanência hospitalar. Esta técnica torna o exame cinecoronariográfico mais simples, menos traumático e menos invasivo
    corecore